22
PLEASE NOTE:
It is generally possible to use the unbalanced and balanced outputs
simultaneously, but slight sound deterioration might occur depending on
the following devices connected. In order to ensure optimal sound
quality, only one output type should be made use of at a time.
Switching between “Pre“ and “Post“
is effected via software:
Press and hold the “LINE“ pushbutton
for about two seconds until the green
LED starts flashing. The present status
is displayed by the “XLR” LED (pre
fader) or the “DIG” LED (post fader).
The setting can be altered now by
pressing the corresponding button. To
complete the setting procedure, just
press and hold the “LINE” button again
until the green LED stops flashing.
LINE-OUTPUT LEVEL
can be set by means of internal DIP switches located on the line-out
circuit board. See page 33 for further details.
Generally, the level at the unbalanced output will equal the input level in
pre-fader mode, or with the level control set fully clockwise in post-fader
mode. By means of the DIP switches however, relative attenuation/gain
can be set to –12, -6, 0, +6 or +12 dB.
Please note that output level at the balanced output is generally +6 dB
higher than at the unbalanced output.
THE “MUTE“ FUNCTION
serves to mute ALL outputs. On the V281, it can only be activated via
remote control.